Achtung: Your browser is outdated. Please note that Gunfinder may not work properly in some places. You should update your browser as soon as possible. Learn more here!
-3 %

REDDING 26400 Case Neck Wall Thickness Gauge with Dial Indicator

204.90 € 198.75 €
72479 Straßberg, Germany
5
ID: 9905202
Shop safely with Gunfinder
Our AI-powered seller identity verification makes Gunfinder the safest marketplace online. Learn more
About the seller
Black Raptor
Dealer

Details

Original language
German
Category
Condition
New
Location
🇩🇪 72479 Straßberg, Germany
Availability
In stock

Freshness

This listing is based on a mirrored offer, where the listing data was synced to us from a shop, dealer, or external marketplace. Please note that temporary price discrepancies may occur due to possible delays in data transmission.
Source
Black Raptor
Last updated
about 11 hours ago

Description

Note: The item is located abroad. Please note that delivery conditions, shipping times, and/or the purchase process may differ.
.br-v3-product{--br-green:#18392f;--br-green-2:#245346;--br-cream:#f5f1e8;--br-gold:#c8a96a;--br-ink:#17211d;--br-line:#d9d3c6;color:var(--br-ink);font:400 16px/1.65 system-ui,-apple-system,BlinkMacSystemFont,"Segoe UI",sans-serif;background:#fff}
.br-v3-product *{box-sizing:border-box}.br-v3-product a{color:#0f5948;text-decoration-thickness:1px;text-underline-offset:3px}.br-v3-product p{margin:.55rem 0}.br-v3-product ul{margin:.65rem 0;padding-left:1.2rem}.br-v3-product li{margin:.25rem 0}.br-shell{max-width:1120px;margin:0 auto;padding:0 18px 32px}.br-hero{padding:30px;border-radius:22px;background:linear-gradient(135deg,var(--br-green),var(--br-green-2));color:#fff}.br-kicker{margin:0 0 8px;color:#f2d49a;font-size:.78rem;font-weight:800;letter-spacing:.12em;text-transform:uppercase}.br-title{margin:0;font-size:clamp(1.75rem,4vw,2.7rem);line-height:1.12}.br-lead{max-width:790px;margin:14px 0 0;font-size:1.08rem;color:#f4f7f5}.br-grid{display:grid;grid-template-columns:repeat(12,1fr);gap:18px;margin-top:18px}.br-card{grid-column:span 6;padding:22px;border:1px solid var(--br-line);border-radius:18px;background:#fff}.br-card-wide{grid-column:1/-1}.br-card-accent{background:var(--br-cream)}.br-card-title{margin:0 0 9px;color:var(--br-green);font-size:1.23rem;line-height:1.3}.br-check{list-style:none;padding-left:0}.br-check li{position:relative;padding-left:1.55rem}.br-check li:before{position:absolute;left:0;color:#17624d;font-weight:900;content:"✓"}.br-facts{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:10px}.br-fact{padding:12px;border-radius:12px;background:#f7f7f4}.br-fact b{display:block;color:var(--br-green);font-size:.83rem}.br-callout{padding:14px 16px;border-left:4px solid var(--br-gold);background:#fff9ec}.br-compare{display:grid;grid-template-columns:repeat(3,minmax(0,1fr));gap:12px}.br-compare-item{padding:14px;border:1px solid var(--br-line);border-radius:14px}.br-compare-item b{display:block;color:var(--br-green);margin-bottom:4px}.br-links{display:flex;flex-wrap:wrap;gap:10px}.br-link{display:inline-block;padding:9px 13px;border:1px solid #7eaa9b;border-radius:999px;background:#fff;font-weight:700;text-decoration:none}.br-faq details{border-top:1px solid var(--br-line);padding:12px 0}.br-faq details:last-child{border-bottom:1px solid var(--br-line)}.br-faq summary{cursor:pointer;color:var(--br-green);font-weight:800}
@media(max-width:760px){.br-shell{padding-inline:12px}.br-hero{padding:22px}.br-card{grid-column:1/-1;padding:18px}.br-facts,.br-compare{grid-template-columns:1fr}.br-link{width:100%;text-align:center}}



Reloading · Measuring and Testing Technology
REDDING 26400 Case Neck Wall Thickness Gauge with Dial Indicator
For reloaders who want to sort cases not only by manufacturer or lot but measurably by uniformity. The gauge makes wall thickness differences on the case neck visible when turning – fast, reproducible, and clearly distinct from runout measurement.



The quick purchase check

Measurement range for cases from .17 to .338 caliber
Dial indicator with 0.001″ graduation
Two mandrels for standard and .060″ flash holes
Pilot gauges for .22 and .30 caliber included
Other calibers require the appropriate REDDING pilot gauge



Who is the gauge worth it for?
It is especially strong for quick lot sorting for precision loadings, benchrest, and long range: multiple cases can be compared with the same routine without repositioning a ball micrometer for each measurement point. Those who miss material for exact neck turning should complement the faster indication of this gauge with a suitable ball micrometer.


Compatibility and avoiding wrong purchases


Caliber range .17 to .338 with matching pilot gauge

Included pilots .22 and .30 caliber

Dial indicator 0.001″ graduation

Mandrels 3/16″ and 9/64″; smaller mandrel for .060
″-Primer Pockets

Mounting Stable table base; REDDING clamp 30520 optional

Identity MPN 26400 · UPC 611760264009

Important: The device shows neck wall thickness differences. It is not a gauge for the concentricity of a fully loaded cartridge. For calibers outside .22 and .30, the appropriate stainless steel pilot stop must be purchased separately.


Practical interpretation: What the pointer deflection means


REDDING 26400 Quick comparative measurement on the entire case neck; ideal for sorting many cases by relative uniformity.

Ball micrometer Slower, but often the more precise reference for individual absolute wall thickness values and controlled neck turning.

Concentricity gauge Checks the radial deviation of the case or cartridge. This is a different measurement and not a substitute for neck wall thickness testing.

REDDING points out that a neck wall deviation over 0.0015″ often indicates further material differences in the shoulder and case body. This is a diagnostic hint, not a general rejection limit: lot, application, chamber, and your own precision requirements remain decisive.


User and instructor tips

Only measure clean, empty, and decapped cases.
Mount the appropriate pilot stop and position the case without side load.
Slowly rotate the case completely once; note the smallest and largest reading.
Always measure at the same neck position and evaluate cases only within comparable lots.
Check the dial indicator for smooth operation and reproducible zero setting before a series.



Scope of delivery and limits
Included: REDDING Case Neck Gauge 26400 with dial indicator, stable table base, two mandrels, and pilot stops for .22 and .30 calibers.
Not included: other caliber-specific pilot stops, table clamp 30520, cases, or other reloading accessories.
The exact net weight is not published. Therefore, the Brownells shipping weight was deliberately not adopted as product weight.


Suitable assortments

REDDING
Reloading accessories
Workshop
Range & Precision



Frequently asked questions
Does the REDDING 26400 measure cartridge concentricity? No. It compares the wall thickness around the case neck. A separate concentricity gauge is intended for the concentricity of a case or loaded cartridge.
Which calibers can I measure directly out of the box? The scope of delivery includes pilot stops for .22 and .30 calibers. For other calibers in the supported range from .17 to .338, the respective REDDING pilot stop is required.
What are the two mandrels for? The two mandrels support different case and primer pocket geometries. The smaller 9/64″ mandrel is intended for cases with .060″ primer pockets.
How is a case compared? The empty, decapped case is slowly rotated on the appropriate pilot stop. The difference between the smallest and largest measurement shows the wall thickness deviation in the tested neck area.
Does the gauge replace a ball micrometer? It is more convenient for quick sorting. For absolute individual values or setting during precise neck turning, a suitable ball micrometer can be the better reference.
Does the gauge need to be fixed to the workbench? The stable base allows a steady table setup. For a fixed clamp mounting, REDDING names the separately available table clamp 30520.
Is a deviation over 0.0015″ automatically reject? No. REDDING describes this value as an indication of possible further material differences. Whether a case is rejected depends on lot, chamber, load, and precision goal. (Show description in original language)
.br-product-v3{--br-ink:#17201c;--br-muted:#54615b;--br-line:#d9e0dc;--br-soft:#f5f7f5;--br-deep:#10271d;--br-gold:#f2d58e;color:var(--br-ink);font-size:16px;line-height:1.68;max-width:1040px;margin:0 auto}.br-product-v3 *{box-sizing:border-box}.br-product-v3 p{margin:0 0 12px}.br-product-v3 a{color:#195e43;text-decoration-thickness:1px;text-underline-offset:3px}.br-product-v3 .br-hero-v3,.br-product-v3 .br-final{background:var(--br-deep);border-radius:18px;padding:clamp(24px,5vw,48px);margin:0 0 28px}.br-product-v3 .br-hero-v3,.br-product-v3 .br-hero-v3 p,.br-product-v3 .br-hero-v3 strong,.br-product-v3 .br-hero-v3 span,.br-product-v3 .br-hero-v3 a,.br-product-v3 .br-final,.br-product-v3 .br-final p,.br-product-v3 .br-final strong,.br-product-v3 .br-final span,.br-product-v3 .br-final a{color:#fff!important;opacity:1!important}.br-product-v3 .br-hero-v3 .br-eyebrow,.br-product-v3 .br-final .br-eyebrow{color:var(--br-gold)!important}.br-product-v3 .br-eyebrow{font-size:.78rem;line-height:1.3;letter-spacing:.12em;text-transform:uppercase;font-weight:800;margin-bottom:10px}.br-product-v3 .br-hero-title{display:block;font-size:clamp(1.65rem,4vw,2.55rem);line-height:1.13;margin-bottom:14px;font-weight:850}.br-product-v3 .br-hero-v3 a.br-cta{display:inline-block;margin-top:8px;padding:11px 16px;border-radius:999px;background:var(--br-gold);color:#102119!important;font-weight:800;text-decoration:none}.br-product-v3 .br-section-title{display:block;font-size:clamp(1.18rem,2.5vw,1.42rem);line-height:1.25;font-weight:850;margin:30px 0 13px;color:var(--br-ink)}.br-product-v3 .br-box{background:var(--br-soft);border:1px solid var(--br-line);border-radius:14px;padding:20px;margin:0 0 18px}.br-product-v3 .br-grid{display:grid;grid-template-columns:repeat(2,minmax(0,1fr));gap:14px;margin:0 0 18px}.br-product-v3 .br-card{border:1px solid var(--br-line);border-radius:14px;padding:18px;background:#fff}.br-product-v3 .br-card-title{display:block;font-size:1rem;line-height:1.35;font-weight:850;margin-bottom:8px;color:var(--br-ink)}.br-product-v3 .br-table{width:100%;border-collapse:collapse;margin:0 0 18px}.br-product-v3 .br-table th,.br-product-v3 .br-table td{border:1px solid var(--br-line);padding:11px;text-align:left;vertical-align:top}.br-product-v3 .br-table th{background:var(--br-soft);font-weight:850}.br-product-v3 details{border:1px solid var(--br-line);border-radius:12px;background:#fff;padding:0 16px;margin:10px 0}.br-product-v3 summary{cursor:pointer;font-weight:800;padding:14px 0;color:var(--br-ink)}.br-product-v3 details p{padding:0 0 14px;color:var(--br-ink)}.br-product-v3 .br-note{border-left:4px solid #b78c2c}.br-product-v3 .br-safe{border-left:4px solid #8a2e2e}@media(max-width:640px){.br-product-v3{font-size:15.8px;line-height:1.62}.br-product-v3 .br-grid{grid-template-columns:1fr}.br-product-v3 .br-hero-v3,.br-product-v3 .br-final{padding:24px 20px;border-radius:14px}.br-product-v3 .br-box,.br-product-v3 .br-card{padding:16px}.br-product-v3 .br-table{font-size:14px}}



REDDING · Wiederladen · Mess- und Prüftechnik
26400 Hülsenhals-Wandstärkenlehre: Materialunterschiede sichtbar machen, bevor sie zur Präzisionsfrage werden
Die REDDING 26400 vergleicht die Wandstärke rund um den Hülsenhals und ist für Wiederlader gedacht, die Hülsen innerhalb eines Loses reproduzierbar sortieren möchten. Sie arbeitet mit Messuhr und kaliberspezifischem Pilotanschlag – und ist bewusst keine Rundlauflehre.
Wichtig vor dem Kauf: Direkt enthalten sind Pilotanschläge für .22 und .30. Für andere Kaliber im unterstützten Bereich von .17 bis .338 wird der passende REDDING-Pilotanschlag separat benötigt.


Unsere ehrliche Einordnung
Die 26400 ist besonders dann sinnvoll, wenn viele Hülsen schnell auf relative Gleichmäßigkeit geprüft werden sollen. Sie ersetzt kein Kugelmikrometer für jeden denkbaren Messzweck und auch keine Rundlauflehre. Ihr Vorteil liegt in einem wiederholbaren Vergleichsablauf: Hülse aufsetzen, drehen, kleinsten und größten Wert beobachten und innerhalb eines Loses vergleichen.



Passt gut, wenn … … du Hülsen für Präzisionslaborierungen, Benchrest oder Long Range nach Halswandstärken-Gleichmäßigkeit sortieren möchtest.
… du mehrere Hülsen in derselben Messroutine vergleichen willst.
… du .17 bis .338 bearbeitest und den passenden Pilotanschlag einplanst.


Passt eher nicht, wenn … … du den Rundlauf einer fertigen Patrone messen möchtest.
… du absolute Wandstärkenwerte ausschließlich mit einem Kugelmikrometer erfassen willst.
… du erwartest, dass für jedes Kaliber bereits ein Pilot im Lieferumfang liegt.



Merkmale und Praxisnutzen


0,001″-Messuhr Die feine Teilung macht relative Unterschiede am Hals schnell sichtbar. Entscheidend ist nicht ein Einzelwert, sondern die reproduzierbare Differenz innerhalb derselben Messroutine.


.17 bis .338 Der unterstützte Bereich ist breit, aber der Pilot muss zum Kaliber passen. .22 und .30 sind direkt abgedeckt; weitere Piloten sind separat zu wählen.


Zwei Mandrels Enthalten sind 3/16″ und 9/64″; der kleinere Mandrel ist für Hülsen mit .060″-Zündloch vorgesehen.


Schnelles Sortieren Für größere Hülsenlose ist die feste Lehre komfortabler als jedes Mal ein Handmessgerät neu anzusetzen. Für exakte Einzelmessungen kann ein Kugelmikrometer trotzdem die bessere Referenz sein.



Was der Zeigerausschlag bedeutet
Die Hülse wird am passenden Pilotanschlag langsam gedreht. Die Differenz zwischen kleinstem und größtem Messwert zeigt die Wandstärkenabweichung am geprüften Halsbereich. REDDING weist darauf hin, dass eine Abweichung über 0,0015″ häufig auf weitere Materialunterschiede in Schulter und Hülsenkörper hindeuten kann. Das ist ein Diagnosehinweis – kein universeller Ausschussgrenzwert.

Grenzen, Nachteile und Fehlkaufvermeidung

Keine Rundlauflehre: Die 26400 misst Halswandstärken-Unterschiede, nicht die radiale Abweichung einer geladenen Patrone.
Nicht jedes Kaliber direkt aus dem Karton: Enthalten sind .22- und .30-Piloten. Andere Kaliber benötigen den passenden separaten Pilotanschlag.
Relative Messung mit Praxisfokus: Wer für Halsdrehen absolute Einzelwerte als Referenz braucht, sollte ein geeignetes Kugelmikrometer ergänzen.


Technische Daten mit Praxisdeutung


Modell
REDDING 26400 Case Neck Gauge – eindeutige Herstellerkennung für diese Lehre.


Messbereich
Hülsen von .17 bis .338 mit passendem Pilotanschlag.


Messuhr
0,001″-Teilung – geeignet für reproduzierbare Vergleichsmessungen am Hülsenhals.


Enthaltene Piloten
.22 und .30 – für andere Kaliber ist der passende REDDING-Pilot separat erforderlich.


Mandrels
3/16″ und 9/64″; der kleinere 9/64″-Mandrel ist für .060″-Zündlöcher vorgesehen.


Montage
Stabile Tischbasis; REDDING-Klemme 30520 optional.


Shopify-SKU
749101759 – Lieferanten-/Shopkennung, nicht mit der Hersteller-MPN 26400 verwechseln.



Praxis- und Sicherheitshinweise
Nur saubere, leere und entzunderte Hülsen messen. Den zum Kaliber passenden Pilotanschlag verwenden und die Hülse ohne Seitenlast langsam drehen. Immer an derselben Halsposition messen und nur vergleichbare Lose miteinander bewerten. Messuhr und Auflage vor einer Serie auf leichtgängigen Lauf und reproduzierbare Nullstellung prüfen.

Lieferumfang

Enthalten: REDDING 26400 Hülsenhals-Wandstärkenlehre mit Messuhr, Tischbasis, zwei Mandrels sowie Pilotanschläge für .22 und .30 Kaliber.
Nicht enthalten: weitere kaliberspezifische Pilotanschläge, optionale Tischklemme 30520, Hülsen oder sonstiges Wiederladezubehör.


FAQ
Misst die REDDING 26400 den Patronenrundlauf? Nein. Sie vergleicht die Wandstärke rund um den Hülsenhals. Für den Rundlauf ist eine eigene Rundlauflehre vorgesehen.
Welche Kaliber kann ich direkt aus dem Karton messen? Enthalten sind Pilotanschläge für .22 und .30. Für weitere Kaliber im Bereich .17 bis .338 wird der passende REDDING-Pilot benötigt.
Wozu dienen die zwei Mandrels? Sie unterstützen unterschiedliche Zündlochgeometrien. Der kleinere 9/64″-Mandrel ist für .060″-Zündlöcher vorgesehen.
Ersetzt die Lehre ein Kugelmikrometer? Nicht in jedem Anwendungsfall. Für schnelles Sortieren ist sie sehr praktisch; für absolute Einzelwerte oder kontrolliertes Halsdrehen kann ein Kugelmikrometer die bessere Referenz sein.
Ist eine Abweichung über 0,0015″ automatisch Ausschuss? Nein. REDDING beschreibt das als Hinweis auf mögliche weitere Materialunterschiede. Die Entscheidung hängt von Los, Kammer, Laborierung und Präzisionsziel ab.


Black Raptor · Kaufentscheidung
Eine Speziallehre für sauberes Hülsensortieren – nicht für jeden Messzweck. Wenn du Halswandstärken innerhalb eines Loses schnell vergleichen willst, ist die REDDING 26400 sehr passend. Wenn dein eigentliches Ziel Rundlauf oder absolute Mikrometerwerte sind, brauchst du ein anderes bzw. ergänzendes Messwerkzeug.

You might also like

Top Auctions

Sponsored listings